Podesite komoru — UKM ClassicPripremamo konfigurator… ← Back to UKM Classic BASIC CONFIGURATION Chamber model Choose a model UKM 1501 – 1 kolicaUKM 1502 – 2 kolicaUKM 1701 – 1 kolicaUKM 1702 – 2 kolicaUKM 2001 – 1 kolicaUKM 2002 – 2 kolicaUKM 2003 – 3 kolicaUKM 2004 – 4 kolicaUKM 2005 – 5 kolicaUKM 2006 – 6 kolicaUKM 2007 – 7 kolicaUKM 2008 – 8 kolicaUKM 2001×2 – 2 kolica, dvoredna konfiguracijaUKM 2002×2 – 4 kolica, dvoredna konfiguracijaUKM 2003×2 – 6 kolica, dvoredna konfiguracijaUKM 2004×2 – 8 kolica, dvoredna konfiguracijaUKM 2005×2 – 10 kolica, dvoredna konfiguracija Heating method Choose a heating method E – electric heating G – gas heating D – steam heating CHOOSE OPTIONAL EQUIPMENT 01Controls and automation SMART configurationIncludes pneumatic door opening, M2016 controller and signal light. SMART configuration for a pass-through chamberThe SMART pass-through configuration includes an M2016 controller, pneumatic door opening, signal light and safety door interlock. M2016 touchscreen controller (upgrade from M2015)The upgrade includes removal of the standalone M2015 control panel. Additional M2015 control panelAdds another M2015 panel for displaying values or controlling the chamber from two locations. Additional M2016 touchscreen control panelAdds another M2016 control panel; one panel can control up to six chambers. Removal of the M2016 control panel from the configurationRemoves the M2016 panel when several chambers are connected to fewer shared panels. VisuNET Premium licence for three computersExtended VisuNET licence for use on three computers. 02Cooling and air treatment Cold-smoking evaporator – 4.5 kW per trolleyCooling evaporator for cold-smoking processes, rated at 4.5 kW per trolley. Intensive cold-smoking evaporator – 7.5 kW per trolleyIntensive cooling for cold smoking and faster moisture removal from products. ClimapacketPackage comprising a cooling evaporator, additional electric heating and a frequency inverter. ShoweringAdds a product showering system inside the chamber. Airflow reversal dampersDampers change the airflow direction through the chamber. Multi-position dampersAllow dampers to be set to multiple positions to direct airflow. Frequency inverterAllows fan speed adjustment. Smoke catalystFor smaller models. UKM 2005–2008 and double-row models from 2003×2 require a smoke afterburner system. Smoke afterburner systemAlternative to a catalyst for UKM 2005–2008, 2003×2, 2004×2 and 2005×2; specified for the project. Extraction fanOptional for UKM 1501, 1502, 1701, 1702, 2001 and 2002; included as standard on the other listed models. 03Construction, doors and installation Overhead rail (includes chamber adaptation)For single-row UKM 2001–2008 models and double-row models from UKM 2002×2. Pass-through chamberAdds doors on both sides of the chamber for pass-through operation. Pass-through chamber for temperatures above 160 °CPass-through configuration for processes above 160 °C. Safety door interlock for a pass-through chamberPrevents simultaneous opening of doors on both sides of the chamber; included in the SMART configuration. Signal light for a pass-through chamberThe signal light indicates the pass-through chamber’s operating status. Pneumatic door openingIncluded in the SMART configuration. Floor drainAdds a floor drain; two drains are recommended for chambers holding six or more trolleys. Air compressorSupplies compressed air to the chamber’s pneumatic components. Chamber weldingIncludes welding of the chamber itself; installation conditions are specified separately. Smoke generator relocationAllows the smoke generator to be positioned away from the front of the chamber or smoke to be fed from above. Electrical cabinet relocationAllows the electrical cabinet to be positioned away from the front of the chamber or in a non-standard location. 100 mm panels with mineral wool fillingReplaces standard panels with 100 mm panels filled with mineral wool. Guillotine door on the front or rear panelAdds a guillotine door to the chamber’s front or rear panel. Door windowAdds a window for visual inspection inside the chamber. Increased floor load capacity up to 1,200 kg per trolleyIncreases the permitted floor load to 1,200 kg per trolley. 04Heating and steam Gas heat exchanger modification for temperatures above 110 °CFor models with gas heating (G). Gas heat exchanger modification for temperatures above 200 °CFor models with gas heating (G). Direct steam injectionIntroduces steam directly into the chamber during processing. Electric heating up to 160 °CFor chambers with electric heating (E). Electric heating up to 200 °CFor chambers with electric heating (E). Additional electric heating for a steam chamber (D) up to 160 °C – fully electric heatingFor steam chambers (D). Additional electric heating for a steam chamber (D) up to 200 °C – fully electric heatingFor steam chambers (D). Additional electric heating for a gas chamber (G) with cooling – 8 kW per trolleyFor gas chambers (G) equipped with a cooling system. Removal of steam group no. 1 from the configurationNot available for UKM 1502 and 1702. Removal of steam group no. 2 from the configurationNot available for UKM 1502 and 1702. 05Smoking system and liquid smoke Complete preparation for liquid smokeFully prepares the chamber for operation with liquid smoke. Preparation of openings for liquid smoke pipeworkPrepares openings for the liquid smoke system’s pipework. Tarber liquid smoke applicatorAdds a Tarber applicator for applying liquid smoke. Smoke pipework with washing systemAdds smoke pipework with an integrated washing system. Removal of the VK01 smoke generatorFor UKM 1501, 1502, 1701, 1702, 2001, 2002 and 2001×2. Removal of the VK02 smoke generatorFor UKM 2003, 2004 and 2002×2. Removal of the VK03 smoke generatorFor UKM 2005–2008, 2003×2, 2004×2 and 2005×2. Removal of the VK04 smoke generatorFor UKM 2007, 2008, 2003×2, 2004×2 and 2005×2. Non-standard smoke generator – specified for the projectThe non-standard smoke generator type is specified separately for the project. 06Washing and auxiliary equipment Additional washing trolleyFor UKM 1501, 1701 and 2001. Removal of the washing trolley from the configurationNot applicable to UKM 1501, 1701 and 2001; available for the other listed models. Dosatron dosing pumpDoses detergent and can be connected to a washing trolley. YOUR CONFIGURATION Chamber modelNo model selected. Heating methodNo heating method selected. ✓Included as standard: VisuNET No optional equipment selected. SENDING AN ENQUIRY SEND YOUR SELECTION TO OUR TEAM Your selected configuration will be added to a prepared email. Prices are not shown in the configurator. SEND AN ENQUIRY→